Solaris 10G系统 双网卡绑定(IPMP协议)异常切换,在网络没有终端,网线良好情况下,从1网口切换到2网口

Solaris 10G系统 双网卡绑定(IPMP协议)异常切换,在网络没有终端,网线良好情况下,从1网口切换到2网口,第1张

v440c-0 console login: root
Password:
Nov 5 15:47:22 v440c-0 login: ROOT LOGIN /dev/console
Last login: Sat Nov 5 15:35:40 on console
Sun Microsystems Inc SunOS 510 Generic January 2005
You have new mail
Sourcing //profile-EIS
root@v440c-0 #
root@v440c-0 # vi /etc/hosts
#
# Internet host table
#
127001 localhost
::1 localhost
192168044 v440 loghost
192168045 v440t-0
192168046 v440t-1
:q
root@v440c-0 # vi /etc/hostnamece1
v440 netmask + broadcast + group group-one up addif v440t-0 deprecated netmask +
broadcast + -failover up
:q
root@v440c-0 # vi hostnamece2
v440t-1 netmask + broadcast + group group-one deprecated -failover up
:q
root@v440c-0 # vi /etc/netmasks
#
# The netmasks file associates Internet Protocol (IP) address
# masks with IP network numbers
#
# network-number netmask
#
# The term network-number refers to a number obtained from the Internet Network
# Information Center
#
# Both the network-number and the netmasks are specified in
# "decimal dot" notation, eg:
#
# 1283200 2552552550
#
19216800 2552552550
:q
root@v440c-0 # vi /etc/defaults
19216801

:q
root@v440c-0 # init 6
测试网络
ce1,ce2 同时合上ping 192168044
切段ce1,ping 192168044
root@v440c-0 # Nov 5 16:27:59 v440c-0 genunix: WARNING: ce1: fault detected external to device; service degraded
Nov 5 16:27:59 v440c-0 genunix: WARNING: ce1: xcvr addr:0x01 - link down
Nov 5 16:27:59 v440c-0 inmpathd[225]: The link has gone down on ce1
Nov 5 16:27:59 v440c-0 inmpathd[225]: NIC failure detected on ce1 of group group-one
Nov 5 16:27:59 v440c-0 inmpathd[225]: Successfully failed over from NIC ce1 to NIC ce2
合上ce1,切段ce2,ping 192168044
root@v440c-0 # Nov 5 16:28:45 v440c-0 genunix: NOTICE: ce1: fault cleared external to device; service available
Nov 5 16:28:45 v440c-0 genunix: NOTICE: ce1: xcvr addr:0x01 - link up 100 Mbps full duplex
Nov 5 16:28:45 v440c-0 inmpathd[225]: The link has come up on ce1
Nov 5 16:28:51 v440c-0 genunix: WARNING: ce2: fault detected external to device; service degraded
Nov 5 16:28:51 v440c-0 genunix: WARNING: ce2: xcvr addr:0x01 - link down
Nov 5 16:28:51 v440c-0 inmpathd[225]: The link has gone down on ce2
Nov 5 16:28:51 v440c-0 inmpathd[225]: All Interfaces in group group-one have failed
Nov 5 16:29:00 v440c-0 inmpathd[225]: NIC repair detected on ce1 of group group-one
Nov 5 16:29:00 v440c-0 inmpathd[225]: Successfully failed back to NIC ce1
Nov 5 16:29:00 v440c-0 inmpathd[225]: At least 1 interface (ce1) of group group-one has repaired
Nov 5 16:29:00 v440c-0 inmpathd[225]: Successfully failed over from NIC ce2 to NIC ce1

网卡速度低,主要要检查网线连接是否正确,包括水晶头,驱动程序是否安装正确,网卡的设置是否正确。
网卡速度关系到网络提供商给你的资源速度,比如电信,网通给你的速度;如果给你的速度不大,还是共享上网的话,网速肯定是不快的。
网卡慢有很多的原因,比如有后台程序占用带宽,例如自动升级的杀毒软件或者病毒,访问的主机本身网络状况不好,所处的位置信号不稳定等等原因都会造成网速不稳定。